Tomzn Tovpd1-60-ec Manual Jun 2026

To adjust the over/under voltage trip points without the app, follow this manual procedure:

After a spike, the power will only turn back on once the voltage drops below this level. 3. Under-Voltage Protection (A3) Display: A3 Range: 140V–210V (Default: 170V) tomzn tovpd1-60-ec manual

To enter the setup mode, press and hold the button for 3 seconds. Use the Up and Down arrows to adjust values. Default Value A1 Over-voltage Protection Value 230V–300V A2 Over-voltage Recovery Value 225V–295V A3 Over-voltage Protection Action Time 0.1s–30s A4 Under-voltage Protection Value 140V–210V A5 Under-voltage Recovery Value 145V–215V A6 Under-voltage Protection Action Time 0.1s–30s A7 Over-current Protection Value A8 Over-current Protection Action Time 0.1s–30s A9 Recovery Delay Time (Power-on time) To adjust the over/under voltage trip points without