Hofmann Duolift Gte 2500 Manual |top| -

The GTE 2500 uses a closed-loop position feedback system (cable extension sensors).

| Interval | Action | |----------|--------| | | Visual inspection of cables, pads, locks. Clean photo-eyes (synchronization sensors). | | Weekly | Test mechanical lock engagement with partial load. | | Monthly | Check hydraulic oil level (ISO VG 32). Top up if needed. | | 6 months | Lubricate pivot points (white lithium grease). Inspect lifting chains for elongation (>3% = replace). | | Annually | Full hydraulic oil change (approx. 2 L per column). Calibrate load cells (requires certified weights or service kit). | | 2 years | Replace all hydraulic hoses (date-stamped). | hofmann duolift gte 2500 manual

Understanding the lift's physical and operational limits is the first step in safe operation. Automotive lifts - Autosfera.lt The GTE 2500 uses a closed-loop position feedback